Part Number Volts
Overall Dimensions
L
in       mm
W
in       mm
H
in       mm
Unit Wt
lb   & kg
Nominal
Capacity 1
Reserve
Capacity 2
AGM-1234T (PDF) 12  7.71  196.0  5.18  132.0  6.89  175.0  24  10.9 33 50
AGM-1240T (PDF) 12  7.71  196.0  5.18  132.0  8.05  205.0  29  13.2 40 61
AGM-1248T (PDF) 12  8.99  228.0  5.45  138.0  8.82  224.0  35  15.9 48 84
AGM-1255T (PDF) 12  8.99  228.0  5.45  138.0  8.82  224.0  39  17.7 55 96
AGM-1265T (PDF) 12  10.22  259.6  6.60  168.0  8.93  259.0  50  22.7 65 121
AGM-1280T (PDF) 12  10.19  259.0  6.60  168.0  8.93  227.0  56  25.5 80 149
AGM-1285T (PDF) 12  12.87  327.0  6.75  171.0  8.96  228.0  62  28.2 85 158
AGM-12100T (PDF) 12  12.01  305.0  6.60  168.0  8.93  227.0  65  29.5 100 186
AGM-12105T (PDF) 12  12.87  327.0  6.75  171.0  8.96  228.0  69  31.3 105 195
AGM-12210 (PDF) 12  20.76  527.0  8.70  221.0  9.76  248.0  135  61.2 210 390
AGM-12255L (PDF) 12  20.72  526.0  10.94  278.0  9.73  247.0  162  73.6 255 475
AGM-6100T (PDF) 10.21  259.3  6.37  161.8  8.92  226.7  42  19.1 100 193
AGM-6220T (PDF) 10.28  261.1  7.06  179.3  10.00  254.0  66  30 220 492
AGM-6300T (PDF) 10.28  261.1  7.06  179.3  13.02  330.8  90  40.8 300 692
AGM-2660T (PDF) 10.28  261.1  7.06  179.3  10.00  254.0  69  31.3 660 1476
AGM-2900T (PDF) 10.28  261.1  7.06  179.3  13.70  331.9  93  42.2 900 2076

Specifications subject to change without notice.

1Nominal Capacity Ampere Hours @ 20 Hr Rate
2Reserve Capacity Minutes of Discharge at @ 25 Amps



Part Number

Description

6918 "A" Type -Automotive Post Terminal adapter kit for "T" batteries only.
6918-12 "A" Type -Automotive Post Terminal adapter kit for "T" batteries only. -- 12 kits per box.
6920 "L" Type -Blade Terminal adapter kit for "T" batteries only.
6920-12 "L" Type -Blade Terminal adapter kit for "T" batteries only. -- 12 kits per box.



CHAIRMAN® BATTERY DESIGN FEATURES
  • Terminals - Copper Alloy Threaded Inserts for improved electrical connections.
  • Terminals are recessed to prevent short circuits across battery connections.
  • Terminal protectors are now available for after connection protection.
  • New cover is a flat top design-No protruding or exposed vent valves.
  • Built in lifting Handles.
  • Reinforced container walls to reduce bulging.
  • High Impact Strength Polypropylene Case and Cover.
  • Valve Regulated Construction.
  • Immobilized Electrolyte - Non-Spillable.
  • Maintenance Free Design Never Requires Watering.
  • Absorbed Glass Mat (AGM) Micro-porous Glass Separators.
  • Flame Arresting Pressure Regulated Safety Valves.
  • UL Recognized Systems Component.
  • Positive Plates - Proprietary Lead Calcium Alloy- Negatives Plates - Lead Calcium.
  • Low Self Discharge Rate Approximately 1 % per month at 25 C (77 F).
  • Operational over a Wide Range of Temperatures, -40 C (-40 F) to +72 C (+160 F).
  • Classified as "Non-Spillable Battery" for Transport. Complies with DOT HMR49 Non-Hazardous Materials.

New "T" Terminal Batteries: The part numbers with the suffix "T" employ the new Copper Alloy Threaded Insert Terminal. Threaded insert is metric M8 except the AGM-1234T & AGM-1240T which are M6. Terminal Options: All "T" type part numbers (except for AGM-1234T & AGM-1240T) are also available with either a copper bolt on "L" blade or a screw on "A" (automotive) type terminal as options. The "L" blade copper terminals accommodate M8 bolts. All batteries are supplied with silicone bronze nuts, bolts, lock washers & washers as applicable. When ordering optional terminal types, add either an "L" or an "A" to the end of the part number and terminal options will be installed at the factory. Inventory Terminal Options: Choosing to stock the standard "T" type terminal will reduce your inventory. You can order the optional "L" or "A" terminal adapter kits listed on the specification and price sheets, reducing inventory requirements and offers your customer additional flexibility. In this case do not add an "L" or an "A" to the end of the part number.

Please note: Part numbers not available with the "T" type threaded insert terminal are the AGM-12210, AGM-12255, & AGM-6100. These parts are available with a copper "L" blade type terminal connection only.

Handles: "T" models = built in handles. Handles not available on part numbers AGM-1248T, AGM-1255T, AGM-6100L and AGM-6220T models. Part numbers AGM-12210 and AGM-12255 are equipped with rope handles.

Ratings: Capacity ratings are stated at 77 F (25 C) to 1.75 volts per cell.

Drawings: Click on the battery part number on the specification sheet above..

Charging Instructions: Initial charge or recharge - 2.37 to 2.40 volts per cell at 25 C (77 F). Float charge - 2.20 to 2.22 volts per cell at 25 C (77 F). Equalize charge - 2.40 volts per cell at 25 C (77 F). Temperature compensation - ±3.75 mV. per cell per degree C [Reference to 25 C (77 F)]. This is for battery temperature (not ambient temperature) and is useful for battery temperatures from 0 C to 40 C. Contact Concorde Battery Corporation for temperatures that exceed this range.
The data/information contained herein has been reviewed and approved for general release on the basis that this document contains no export-controlled information.
Home Page - Site Map - AS 9100 REV. B:2004 & ISO 9001:2000 (pdf) - Battery Transportation Information - AOG Service - Business Hours
Glossary of Terms - Upcoming Events / Trade Shows / Airshows - Distributors - Contact Us - Employment Opportunities

All Rights Reserved. © 1996-2008 Concorde Battery Corporation
Original Database Created by Broomfield Designers Hosted & Maintained by Broomfield-Designers.com

Concorde Battery Produces the Highest Grade Aircraft Batteries,
AGM Batteries and Ni-Cad Batteries in the industry.